APPLICATION NOTE: Using Wind Observer II with MDS Trans NET 900 Radio 12
STARTING CONFIGURATION MODE
After we establish connection with the Wind Observer II we can start the CONFIGURATION MODE as
follows:
Press ENTER key after each command
Enter “*” to start CONFIGURATION MODE.
D3 to see current setting
A0 Speed of sound and temperature disable
B3 9600 Baud rate
C1
E1 Full Duplex
F1 8 bits, no parity, 1 stop bit
G0000 Average period in seconds
J1 Enable analogue power up test
K1 NMEA string “IIMWV”
L1 ASCII Message terminator CR LF
M2 ASCII Polar Continuos
NB B is the unit identifier, can be any letter from B to Z
O1 Message Format = Comma Separated Variable (CSV)
P1 Output rate P1= 1 per second
T1 Voltage o current output (0 to 5V, or +
2.5 V)
U1 Units in m/s
V1 Disable vertical output padding
X1 Aligns U axis with North/South axis
Y1 Chanel 3 Output Y1=status
Z1 Scaling Z1= +
10
D3 To see current settings
Q Return to MEASUREMENT MODE