18 MDS 4710/9710 I/O Guide MDS 05-3305A01, Rev. D
DIN [ON/OFF] Details Page
23
Configures local diagnostic link protocol.
DTYPE [NODE/ROOT]
Details Page 23
(diagnostics) Sets up a radio as a root or node
radio.
DUMP Details Page 23 Display all programmable settings.
HREV Details Page 24 Display the Hardware Revision level.
INIT Details Page 24 Set radio parameters to factory defaults.
INIT [4710/9710] Details
Page 24
Configure radio for use outside of P-20 chassis.
Restores certain transceiver defaults changed by
the INIT x720 command.
INIT [4720/9720] Details
Page 24
Configure radio for service within a P-20
redundant/protected chassis.
KEY Details Page 25 Key the radio (transmitter ON). This is generally a
radio test command.
MODEL Details Page 25 Display the model number of the radio.
MODEM [xxxx, NONE]
Details Page 25
Set the modem characteristics of the radio.
OWM [XXX...] Details Page
25
Set or display the owner’s message.
OWN [XXX...] Details Page
25
Set or display the owner’s name.
PTT [0–255] Details Page
25
Set or display the Push-to-Talk delay in
milliseconds.
PWR [20–37] Details Page
25
Set or display the transmit power setting.
RSSI Details Page 26 Display the Received Signal Strength Indication.
RTU [ON/OFF/0-80] Details
Page 26
Re-enables or disables the radio’s internal RTU
simulator and sets the RTU address.
RX [xxx.xxxx] Details Page
26
Set or display receiver frequency.
RXLEVEL [–20 to +6]
Details Page 27
Set or display the receive audio input level.
RXTOT [NONE, 1-1440]
Details Page 27
Set or display the value of the receive time-out
timer.
SCD [0-255] Details P
age
27
Set or display the Soft-Carrier Dekey delay in
milliseconds.
SER Details Page 27 Display the radio serial number.
SHOW [DC, PORT, PWR]
Details Page 27
Display the DC voltages, diagnostics port, and
transmit power level.
SREV Details Page 28 Display the Software Revision Level.
STAT Details Page 28 Display radio status and alarms.
TEMP Details Page 28 Display the internal temperature of the radio in
degrees C.
TOT [1-255, ON, OFF]
Details Page 28
Set or display the Time-out Timer delay in
seconds.