34 MDS 4710/9710 I/O Guide MDS 05-3305A01, Rev. D
4. Measure the radio’s RSSI using one of the following methods:
With an HHT (See Section 4.0, TRANSCEIVER PROGRAM-
MING on Page 14).
With GE MDS Radio Configuration Software (See Section 6.5,
Upgrading the Radio’s Software on Page 37).
With a voltmeter connected to Pin 21 of the
DATA INTERFACE
connector (See Section 3.2, RSSI Measurement on Page 13).
5. With a non-metallic adjustment tool, adjust each section of the
helical lters for maximum RSSI. Re-install the cover to the trans-
ceiver.
Invisible place holder
Figure 11. Helical Filter Locations
6.3 Performing Network-Wide Remote Diagnostics
Diagnostics data from a remote radio can be obtained by connecting a
laptop or personal computer running GE MDS InSite NMS software to
any radio in the network. Figure 12 shows an example of a setup for per-
forming network-wide remote diagnostics.
FRONT PANEL
OF RADIO
J301
U104
U101
U202
HELICAL
ADJUSTMENTS
U203
SHIELD
COVER